Spot Time Control (Reconfigured Rmt 2T Hold Output Selection) (All Models); Memory (Program Storage Locations 1-4) (Dx And Lx Models If Available) - Miller Maxstar 300 LX Owner's Manual

Hide thumbs Also See for Maxstar 300 LX:
Table of Contents

Advertisement

5-11.

Spot Time Control (Reconfigured RMT 2T HOLD Output Selection) (All Models)

SPO

5-12. Memory (Program Storage Locations 1-4) (DX And LX Models If Available)

1
1st
2nd
Memory Locations
1−4
1
1.0
.
Some features shown are
2
not available on all models.
TIG (HF or Lift)
And
AC
Stick
And
TIG (HF or Lift)
DC
And
Stick
3
Or
Or
Or
2
1
Memory (Program Storage 1-4)
Switch Pad
2
Process Switch Pad
To create, change, or recall a welding pa-
rameters program, proceed as follows:
First, press Memory switch pad until the de-
sired program storage location (1-4) LED is
illuminated
Second, press Process switch pad until de-
sired process, TIG HF Impulse, TIG Lift Arc,
or Stick, LED is illuminated.
The program at the chosen location, for the
desired polarity and process, is now the ac-
tive program.
Fourth, change or set all desired parame-
ters (see Section 5-1 for parameters).
Each memory location (1 thru 4) can store pa-
rameters for both polarities, and each polarity
can store parameters for both process (TIG or
Stick) for a total of 16 programs.
1
Spot Time Meter Display
Select Spot function according to
Section 6-2C.
2
Amperage Switch Pad
3
Encoder Control
To set spot parameters, press Am-
perage switch pad once (meter A
LED turns on) and turn Encoder to
set spot amperage. Press Amper-
age switch pad again, (meter S LED
lights) and turn Encoder to set spot
time (.1−25 seconds). Default is 1
second.
Application: To provide a timed
weld for tacking and thin sheet join-
ing.
OM-2222 Page 31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Maxstar 300 dxMaxstar 300 sd

Table of Contents