• Auto-Idle Display(2)
When selecting auto-idle from the switch panel, the auto-
idle display (2) is displayed.
When the key is turned ON, the data blinks for 10 seconds.
• Overload Alarm Display (3) (optional)
The system measures the load of suspended load from the
bottom pressure of boom cylinder. When overload is de-
tected, an alarm is displayed.
• Auto-Lubrication Display (4) (Optional)
When selecting auto-lubrication from the switch panel, the
auto-lubrication display (4) is displayed.
• Preheat Display (6)
While the current is supplying to the glow plug, the preheat
display (6) is displayed.
• Fuel Rate Display (13)
Fuel consumption is displayed. (Reference value)
OPERATOR'S STATION
T1V1-05-02-002
1-8
3
4
2
6
13
M1J1-01-003