W O L F
E L E C T R I C A L
Wolf downdraft ventilation systems require a
separate, grounded 120 V, 60 Hz power supply.
The service should have its own 15 amp circuit
breaker, and a grounded 3-prong receptacle
should be located within the reach of the 2
I M P O R TA N T
(.8 m) power cord. The specific location of the
N O T E
outlet is not critical, as long as it is within
reach of the power cord that is located mid-
way, top and bottom, on the right side of the
You must follow
downdraft.
all National
Electrical Code
IMPORTANT NOTE: If Model DD30 is to be
regulations. In
installed in a 30" (762) wide cabinet, Model
addition, be aware
DD36 in a 36" (914) wide cabinet or Model
of local codes and
DD45 in a 45
ordinances when
electrical outlet cannot be located on the back
installing your
service.
wall of the cabinet. The outlet can be placed in
an adjacent cabinet within reach of the power
cord. An access hole for the power cord must
be drilled in the cabinet wall.
Choose the electrical location shown in
the illustration below that best suits your
installation.
Location of electrical
8
D OW N D R A F T
V E N T I L A T I O N S Y S T E M S
R E Q U I R E M E N T S
1
/
" (1156) wide cabinet, the
2
24 "
min (610)
CABINET DEPTH
IMPORTANT NOTE: A ground fault circuit
interrupter (GFCI) is not recommended and
may cause interruption of operation.
You must follow all National Electrical Code
1
/
'
2
regulations. In addition, be aware of local
codes and ordinances when installing your
service.
The electrical outlet must be checked by
a qualified electrician to be sure that it is
wired with the correct polarity. Verify
that the outlet provides 120 V AC and is
properly grounded.
Do not use an extension cord or two-
prong adapter. Electrical ground is
required on this appliance. Do not remove
the power supply cord ground prong.
4"
min (102)
1
3
/
"
2
(89)
10"
30"
min (762)
FOR MODEL DD30
36"
min (914)
FOR MODEL DD36
1
45
/
"
2
min (1156)
FOR MODEL DD45
E
E
(254)
OPTIONAL
ELECTRICAL
LOCATION IN
ADJACENT RIGHT
SIDE CABINET

Advertisement

loading

This manual is also suitable for:

Dd30rDd36iDd36rDd45iDd45r