I N S TA L L AT I O N
I N S T R U C T I O N S
For installation of a downdraft system with a
cooktop, refer to the cooktop installation
instructions for the dimensions of the cooktop,
countertop cut-out and cabinet requirements.
The depth of the cooktop may vary and will
affect the location of the downdraft in the
countertop.
The illustration below provides countertop
cut-out dimensions for downdraft Models
DD30, DD36 and DD45 installed with a Wolf 30"
(762) or 36" (914) cooktop or combination of
cooktop and/or modules.
IMPORTANT NOTE: For installation of a
downdraft with sealed burner rangetop Models
SRT304 and SRT366, an accessory trim kit
(SRT/DDTRIM) is necessary. Contact your
Wolf dealer for details. To obtain local dealer
information, visit the Locator section of our
website, wolfappliance.com.
FOR MODEL DD30
1 /8
25
"
FOR MODEL DD36
min
(638)
FLAT
FOR MODEL DD45
COUNTERTOP
SPACE
COOKTOP CUT-OUT
COUNTERTOP TOP VIEW
Countertop cut-out dimensions
Dimensions in parentheses are in
millimeters unless otherwise specified.
C O N T R O L M O D U L E L O C A T I O N
Installation of the remote-mounted control
module can be located anywhere within 10'
(3 m) of the downdraft assembly and a
minimum of 4" (102) from the outer edge of
cooktop element or burner. You will be
required to drill three holes and connect the
control module to the downdraft assembly
using the cable provided.
The remote-mounted control module is
2
horizontally or vertically in the countertop. A
1" (25) diameter hole for the RJ45 connector
cable will be centered horizontally and verti-
cally in the back side of the control module.
Two
screws will be located 2" (51) from the center
of the RJ45 connector cable hole, one on each
side. Additional installation instructions are
provided with the control kit.
Mark the center of the control module on the
counter top. Measure 2" (51) up (or left) and 2"
(51) down (or right) to locate holes for the
mounting screws.
IMPORTANT NOTE: The length of the control
module cable is 10' (3 m). You must plan the
installation of the control module to be within
10' (3 m) of the downdraft assembly.
3 /4
2
27"
(686)
33"
(838)
42"
(1067)
19
WIDTH
1 /2
2
"
min (64)
3
5
/
" (60) x 6
/
" (168) and can be positioned
8
8
1
/
" (6) diameter holes for the mounting
4
"
(70)
1 /4
"
(489)
7

Advertisement