Download Print this page
Wolf DD30I Installation Instructions Manual
Wolf DD30I Installation Instructions Manual

Wolf DD30I Installation Instructions Manual

Wolf dd30i downdraft ventilator: install guide
Hide thumbs Also See for DD30I:

Advertisement

Quick Links

D
V
O W N D R A F T
E N T I L A T I O N
I
I
NSTALLATION
NSTRUCTIONS

Advertisement

loading

Summary of Contents for Wolf DD30I

  • Page 1 O W N D R A F T E N T I L A T I O N NSTALLATION NSTRUCTIONS...
  • Page 2 800-332-9513 Website: wolfappliance.com ® WOLF is a registered trademark of Wolf Appliance Company, Inc. As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equip- ment.
  • Page 3 Make sure you have the tools and materials necessary for proper installation. Any required service must be performed by a Wolf authorized service center. Wolf is not responsible for service required to correct a faulty installation. R AT I N G P L AT E...
  • Page 4 30" (762), 36" (914) and 45 (1156) widths. The downdraft should be at least as wide as the cooktop. Models DD30I, DD36I and DD45I include a 500 CFM internal blower. Models DD30R, DD36R and DD45R are shipped without a blower assembly.
  • Page 5 1200 CFM Remote Blower 1500 CFM Remote Blower IMPORTANT NOTE: Blower options vary with the cooking surface. For recommendations, refer to the Wolf Design Guide found on the Wolf website, wolfappliance.com. IMPORTANT NOTE: Install this downdraft ventilation system only with a Wolf blower.
  • Page 6 CABINET DEPTH AREAS OF POTENTIAL INTERFERENCE IMPORTANT NOTE: To install a downdraft system and a Wolf cooktop, you must allow for a minimum 25 " (638) flat counter space from front to back. A countertop with a raised lip or backsplash may not allow enough space for proper installation.
  • Page 7 The illustration below provides countertop cut-out dimensions for downdraft Models DD30, DD36 and DD45 installed with a Wolf 30" (762) or 36" (914) cooktop or combination of cooktop and/or modules. IMPORTANT NOTE: For installation of a...
  • Page 8 D OW N D R A F T E L E C T R I C A L Wolf downdraft ventilation systems require a separate, grounded 120 V, 60 Hz power supply. The service should have its own 15 amp circuit...
  • Page 9 IMPORTANT NOTE: Blower options vary with the cooking surface. For recommendations, refer to the Wolf Design Guide found on the Wolf website, wolfappliance.com. CENTERLINE OF COUNTERTOP CUT-OUT 1 /8 "...
  • Page 10 Use only metal ductwork. Wolf downdraft ventilation systems are designed for use with 3 ductwork for Models DD30I, DD36I and DD45I, and 3 " (83) x 14" (356) ductwork for Models DD30R, DD36R and DD45R. Each can be transitioned to 8"...
  • Page 11 A D J U S T I N G B L OW E R D I S C H A R G E Wolf downdraft systems have an adjustable discharge that will allow you to negotiate ducting around floor joists and other obstacles.
  • Page 12 W O L F D OW N D R A F T D O W N D R A F T C U T T H E C O U N T E R T O P Lay out and cut the cooktop cut-out far enough forward so the downdraft will fit behind it.
  • Page 13 IMPORTANT NOTE: For installations where the ductwork is riveted to the unit, a 3 x 10" (254) collar is provided for Models DD30I, DD36I and DD45I, and a 3 " (83) x 14" (356) collar is provided for Models DD30R, DD36R and DD45R.
  • Page 14 W O L F D OW N D R A F T D O W N D R A F T R E M O T E B L O W E R W I R I N G Models DD30R, DD36R and DD45R Mount a standard 120 V AC electrical box, with 3-pronged grounded receptacle, inside the cabinet or adjacent cabinet.
  • Page 15 Neither this book nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Wolf Appliance Company, Inc., an affiliate of Sub-Zero Freezer Company, Inc. ©Wolf Appliance Company, Inc. all rights reserved.
  • Page 16 W O L F A P P L I A N C E C O M PA N Y, I N C. P. O. B OX 4 4 8 4 8 M A D I S O N , W I 5 3 7 4 4 8 0 0 - 3 3 2 - 9 5 1 3 W O L FA P P L I A N C E .

This manual is also suitable for:

Dd30rDd36iDd36rDd45iDd45r