3.2.3. Hardware installation Instruction
•
Power down the AX-201.
•
Lock the main switch with a padlock
•
Remove the right side cover to be
able to access the rear of the aPC
and aSC
•
Pull out the control supply unit at the
rear of the machine.
•
In case the machine is not equipped
with an Ethernet Hub, these steps
are not necessary. Disconnect the
crosslink cable between X63 of the
aPC and X63 of the aSC.
•
Discard the cable
•
Place the Ethernet switch in the base
underneath the aSC and aPC
•
Take the power cable from the
Ethernet Switch and lead this to the
front of the machine
•
Connect the new Ethernet cables
from the HUB to the X63 of the aPC
and the X63 of the aSC
•
Place the power connection block in
front of the machine
•
Connect 220V power cable for the
SVS Pro controller into the power
connection block
•
Connect the power cable from the
ethernet switch box.
•
Place the FireSync controller and
power supply in front of the machine
•
Connect a Ethernet cable from the
Switchbox to the 'OUT' connector of
the FireSync controller. Lead the
cable trough the opening in the base
beside the aPC.
•
Connect 220V power from the
extension cord to the power
connection block PCA L1 (position
X3).
•
Connect 12V cable from the power
supply to the FireSync station.
•
Place Power supply for Coplanarity
sensor in base.
•
Connect 220V cable to Power PCB
L3 (position X6).
•
Connect LMI cable to 48v connection
of Power supply for Coplanarity
sensor.
16