4.2. User instruction

The production on an AX-201 with coplanarity checker is the same as without checker. Except for the
following;
The run placement program must be created by the special PPS-Pro version that is
capable to create programs with the use of the coplanarity checker.
In the operator screen the checker is visible:
When the coplanarity checker is enabled, for the applicable components a coplanarity
check is performed after the alignment process. (it is not possible to perform coplanarity
check before an alignment)
Possibility to disable the coplanarity checker in the 'Setup - Operational settings' screen:
Restriction in changing component files.
The AX-201 and the coplanarity checker use a different file (Settings.xml and
"componentname".cmp) as data source for their processes. A component name change
for components that are checked on coplanarity must be changed in both files. See
chapter 3.3.2.3.