5.3.2. Laser sensor module

When
Estimated time to complete [min.]: 30
Required special tools
Required part(s)
1. Prerequisites
Contact your local service engineer.
Order a NEW laser sensor unit.
NOTE: It is not allowed to open, trouble shoot or
repair parts of the Laser sensor unit in or outside the
AX-201. All warranty will expire.
2. Remove the Sensor Unit
Switch off and power down the AX-201
Lock the main switch with a pad-lock
Disconnect the Sensor connection cable
and the safety extension cable.
Loosen the two bolds.
Remove the unit from the base
3. Place the new sensor unit
Place the new unit completely over the
dowel pins
Fasten the two bolds.
Check the serial number in the
'settings.xml'. See Chapter 3.3.2.2
Connect the sensor cable to the sensor.
Connect the safety cable to the safety
extension cable.
Power up the AX-201.
Follow the teach X, Y coordinates
procedure (See chapter 3.3.2.5)
If the laser sensor is not working
N.A.
New Laser sensor unit (9466-916-00051)