Software Installation; Parts; Cal.cfg - Philips AX-201 Option Manual

Table of Contents

Advertisement

3.3. Software installation

3.3.1. Parts

With the coplanarity checker, 3 files are changed or introduced in the AX-201.
The cal.cfg (only changed), the cpl.cfg and the settings.xml

3.3.1.1. cal.cfg

The cal.cfg new fields are added with reference to the position of the coplanarity checker on the AX-
201.
The new files are:
[COPLANARITY_UNIT_FRONT]
; MCS position of measurement beam centre
UNIT_REF_POS_XY
; MCS Z-level of measurement beam. This is the reference level
UNIT_REF_POS_Z
; X offset w.r.t. UNIT_REF_POS_XY to be applied as starting
; point for trajectory to measurement centre [in mm]
FLY_IN_ZONE
; X offset w.r.t. UNIT_REF_POS_XY to be applied as end
; point for trajectory to measurement centre [in mm]
FLY_OUT_ZONE
[COPLANARITY_UNIT_REAR]
; MCS position of measurement beam centre
UNIT_REF_POS_XY
; MCS Z-level of measurement beam. This is the reference level
UNIT_REF_POS_Z
; X offset w.r.t. UNIT_REF_POS_XY to be applied as starting
; point for trajectory to measurement centre [in mm]
FLY_IN_ZONE
; X offset w.r.t. UNIT_REF_POS_XY to be applied as end
; point for trajectory to measurement centre [in mm]
FLY_OUT_ZONE
18
= -344.228, 6.0
= 15.0
= 4.0
= 12.0
= -6.244, 663,816
= 15.0
= 4.0
= 12.0