3.3.2.5. Teach x, y coordinates.
Before the AX-201 can use the coplanarity checker it is mandatory to first load the placement programs
from PPS Pro (see chapter 3.4), create an order and measure the place (X and Y coordinate) of the
installed checker and update the "cal.cfg".
•
Go to the teach menu and use the
BA camera to measure the
coordinates of the marker in
between CA1 & CA2
•
Store the correction and write this
value down. This is point 'A'.
•
Now jog to the centre of the
coplanarity checker
Point "B" if placed on the front side,
"C" if placed at the rear side.
o The centre of the
coplanarity checker is
given in point 'D'.
o An example of the immage
on the machine is given at
point 'E'.
•
Select "OK".
•
Writhe down the values from the
"change' field.
•
Open the "cal.cfg" file in the
'user\apc\diag' folder.
•
For front side, fill out the values
from the change field in the "
HEAD_MARKER_POS_XY " field.
•
For rear side, Subtract the values
from the 'change' field from the
'current' field. Fill out the value in
the HEAD_MARKER_POS_XY field
of the [CA_UNIT_REAR] block.
•
Save the cal.cfg file.
•
Close the TEACH window without
saving changes to the placement
program/order.
•
Power-down the AX-201.
•
Power-up.
28