Haier GE PTW600BPR DG Series Technical Service Manual page 68

Profile 28-in. top load washer
Table of Contents

Advertisement

Name
Description
58 ADC Health
This fault is set when
Check Fault
any ADC Self-Diagnosis
channel reports an out-
of-tolerance value for
10-seconds.
65 Pressure
The pressure sensor loss
Sensor
algorithm set conditions
Continuous
are described here: Flood
Gallons Monitor
Protection Algorithm
76 Bulk sensor not
Bulk sensor reads:
connected or
out of range
78 Board
The main board detects
Communication
that it doesn't have the
API Mismatch
same API version as
another board.
79 Voice Module
No communication
Heartbeat
between the Voice
Failure
Module and MC detected
for 10 seconds.
86 Extremely Low
Current Water Level
Water Pressure
Cycle Step Low Pressure
Check is ran < 0.85 *
Minimum Fill Level.
92 Inverter
No heartbeat from
Heartbeat
the inverter to the MC
Failure
detected for 60-seconds
86 Extremely Low
Current Water Level
Water Pressure
Cycle Step Low Pressure
Check is ran < 0.85 *
Minimum Fill Level.
91 User Interface
No communication
(UI): Main
between the User
Board
Interface (UI) and Main
Heartbeat
Control Board (MCB)
Timeout
detected for 10-seconds.
• Not connected (> =
4.84V)
• Empty (< 2.00V)
Repair Action
• Replace main board.
• See Fault Code 25.
• Check bulk tank level sensor harness
connections.
• If the above repair actions don't clear the fault,
replace bulk tank sensor.
• Use SmartHQ diagnostic tool or use a SUM
module to update the software.
• Check voice module harness connections.
• If the above actions don't clear the fault,
replace voice board and harness.
• If the above actions don't clear the fault,
replace user interface (UI) board.
• See Fault Code 25.
• Run Spin Test 14. If cycle completes, no
repair needed and clear faults.
• Check line voltage for 102 VAC to 132 VAC.
• Check all inverter board harness connections.
• Check Motor TCO continuity at J502 (inverter
board). If open, should reset after 45-minutes.
• Check for continuity through each pair of
motor phase windings at J401 (inverter). If
any discontinuities, replace motor.
• See Fault Code 25.
• Check User Interface (UI) harness
connections.
• Check Main Control Board (MCB) to User
Interface (UI) voltages.