Power Requirements - HP NetServer LH 6000 Installation Manual

Table of Contents

Advertisement

Appendix A
Weight and Dimensions
NOTE
A fully loaded HP NetServer can weigh up to 173 lbs. (78.5
kgs). Follow local regulations, and use one person for every 40
pounds of HP NetServer weight when lifting it.
HP NetServer LH 6000
Height
Width
Depth
Weight
HP NetServer LH 6000r
Height
Width
Depth
Weight

Power Requirements

Power Supply Specifications: Three power supplies, plus one for redundancy
Power supply type
Input voltages:
Nominal:
Range:
Power availability:
Minimum System Requirements
Voltage
100
120
200
230
All manuals and user guides at all-guides.com
494.8 mm (19.5 in)
350.5 mm (13.8 in)
724.2 mm (28.5 in)
72.6 – 78.5 kg (160 - 173 lb.)
354.7 mm (14 in)
482.6 mm (19 in)
749.2 mm (29.5 in)
72.6 – 78.5 kg (160 - 173 lb.)
Wide range, PFC
100 to 240 VAC, 11.7A/5.6 A at 50/60 Hz
90 to 264 VAC at 47 - 63 Hz
780 W continuous
Volt/Amps
1177
1153
1120
1117
Specifications
Amps
Watts
11.7
1166
9.6
1141
5.6
1099
4.9
1095
159