GEM 650TL Operating Instructions Manual page 34

Manually operated diaphragm valve
Table of Contents

Advertisement

17 Troubleshooting
Error
Handwheel cannot be turned
Proximity switches also respond in the
open position
GEMÜ 650TL
Possible cause
Handwheel faulty
Stroke limiter and seal adjuster incor-
rectly set
Use of wrong proximity switches
Damping piece incorrectly adjusted
34 / 42
Troubleshooting
Replace the handwheel for diaphragm
size 8. Replace the actuator for dia-
phragm size 10 and 25.
Release and reset stroke limiter and seal
adjuster
Only use M8x1 proximity switches which
can be mounted flush
Reset damping piece
www.gemu-group.com