4
FUNCTIONS
(2) Operation in auto refresh
Allocate as
follows:
RX to X400
RY to Y400
RWw to W0
RWr to W100
SB to SB0000
SW to SW0000
Safety remote I/O station
Station No.1
Station No.2
Station No.4
Station No.5
Station No.1
Station No.2
Station No.4
Station No.5
Station No.1
Station No.2
Station No.4
Station No.5
Station No.1
Station No.2
Station No.4
Station No.5
4
- 10
4.2 Detailed Explanation of Functions
4.2.3 Auto refresh function
When the auto refresh parameters are set, the relation between the CPU devices and
the refresh-target devices (remote input (RX), remote output (RY), remote registers
(RWr, RWw), link special relay (SB) and like special register (SW)) is as shown on the
system configuration example below.
Station No.1
1 occupied station
Remote
device station
The relation between the CPU devices and the devices of each remote station is as
shown below. Note that this figure is illustrated based on the following setting: remote
input (RX) is set to X400, remote output (RY) is set to Y400, remote registers (RWr,
RWw) are set to W0 and W100 respectively, link special relay (SB) is set to SB0000
and link special register (SW) is set to SW0000.
Safety CPU module
Safety master module
X41F to X400
RX1F to RX00
X43F to X420
RX3F to RX20
X45F to X440
RX5F to RX40
X47F to X460
RX7F to RX60
X49F to X480
RX9F to RX80
X4BF to X4A0
RXBF to RXA0
W3 to W0
Used by the system
W7 to W4
RWr7 to RWr4
WB to W8
RWrB to RWr8
WF to WC
RWrF to RWrC
W13 to W10
RWr13 to RWr10
W17 to W14
RWr17 to RWr14
Y41F to Y400
RY1F to RY00
Y43F to Y420
RY3F to RY20
Y45F to Y440
RY5F to RY40
Y47F to Y460
RY7F to RY60
Y49F to Y480
RY9F to RY80
Y4BF to Y4A0
RYBF to RYA0
W103 to W100 *1
Used by the system
W107 to W104
RWw7 to RWw4
W10B to W108
RWw13 to RWw8
W10F to W10C
RWwF to RWwC
W113 to W110
RWw13 to RWw10
W117 to W114
RWw17 to RWw14
SB1FF to SB0
SB1FF to SB0
SW1FF to SW0
SW1FF to SW0
*1: The CPU devices assigned to RWw of safety remote I/O stations are not refreshed automatically.
Safety CPU module
Safety master module
Station No.2
2 occupied stations
Standard remote
I/O station
Safety remote I/O station
Remote device station
(Station No.1, 1
(Station No.2, 2
occupied station)
occupied stations)
X1F to X00
Used by the system
Y1F to Y00
Used by the system
Remote device station
Station No.5
2 occupied stations
Station No.4
1 occupied station
Standard remote I/O station
(Station No.4, 1
occupied station)
RX1F to RX00
RX3F to RX20
X1F to X00
RWr3 to RWr0
RWr7 to RWr4
RY1F to RY00
RY3F to RY20
Y1F to Y00
RWw3 to RWw0
RWw7 to RWw4
Remote device station
(Station No.5, 2
occupied stations)
RX1F to RX00
RX3F to RX20
RWr3 to RWr0
RWr7 to RWr4
RY1F to RY00
RY3F to RY20
RWw3 to RWw0
RWw7 to RWw4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-qs0j61bt12

Table of Contents