Mitsubishi Electric MELSEC QS Series User Manual page 125

Cc-link safety system master module
Hide thumbs Also See for MELSEC QS Series:
Table of Contents

Advertisement

8
PROGRAMMING SPECIFICATIONS
Number
Name
Indicates the retry count setting information when there is an error
SW0064
No. of retries
response.
(664
)
information
H
1 to 7 (times)
No. of
Indicates the setting information for the number of automatic return
SW0065
automatic
stations during one link scan.
(665
)
H
1 to 10 (stations)
return stations
SW0066
Delay timer
Fixed to 0 (
(666
)
information
H
SW0067
Parameter
Stores the parameter information area to be used.
0
(667
)
information
H
Host
Stores the parameter setting status.
SW0068
0
parameter
(668
)
H
1 to
status
Stores the overlap station number status and parameter consistency of
each station.
SW0069
Installation
0
(669
)
status
*3
H
1 to
Stores the switch setting status.
SW006A
Switch setting
0
(66A
)
status
H
1 to
SW006D
Max. link scan
Stores the maximum value of the link scan time.
(in 1ms units)
(66D
)
time
H
SW006E
Current link
Stores the current value of the link scan time.
(in 1ms units)
(66E
)
scan time
H
SW006F
Min. link scan
Stores the minimum value of the link scan time.
(in 1ms units)
(66F
)
time
H
SW0070
Total number
Stores the last station number set in the parameter.
1 to 64 (stations)
(670
)
of stations
H
Max.
Stores the highest station number (setting of the station number setting
SW0071
connected
switch) among stations that are performing data link.
(671
)
H
1 to 64 (stations)
station number
Number of
SW0072
connected
Stores the number of modules that are performing data link.
(672
)
H
modules
SW0074
Stores the reserved station setting status.
0 : Other than reserved station
(674
)
H
1 : Reserved station
SW0075
Reserved
(675
)
H
station
SW0074
specification
SW0076
SW0075
status
*6
(676
)
H
SW0076
SW0077
SW0077
(677
)
H
* 1 Safety remote net (Ver. 1 mode)
* 2 Off line, Hardware test or Line test.
* 3 This register checks and stores the status only at link startup.
* 6 Only the bit for the head station number is turned on.
Table8.6 Link Special Register List (3/7)
Description
s)
: CPU built-in parameters (Fixed)
H
: Normal
: Stores an error code (see Section 9.5)
: :Normal
: Stores an error code (see Section 9.5)
Details are stored in SW0098 to 9B and SW009C to 9F.
: Normal
: Stores an error code (see Section 9.5)
b15
b14
b13
b12
16
15
14
13
32
31
30
29
48
47
46
45
64
63
62
61
Numbers 1 to 64 in the above table indicate the station numbers.
8.3 Link Special Relays and Registers (SB/SW)
8.3.2 Link special registers (SW)
to
b3
b2
b1
b0
4
3
2
1
to
to
20
19
18
17
to
36
35
34
33
to
52
51
50
49
Availability
(
:Available,
:Not available)
1
Online*
SAFETY
TEST
Offline*
MODE
MODE
8
- 22
1
2
2
3
4
5
6
7
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-qs0j61bt12

Table of Contents