Mitsubishi Electric MELSEC QS Series User Manual page 111

Cc-link safety system master module
Hide thumbs Also See for MELSEC QS Series:
Table of Contents

Advertisement

8
PROGRAMMING SPECIFICATIONS
(2) Remote input (RX) and remote output (RY)
Safety master station
Address
Remote output (RX)
E0h
For station No.1
E1h
E2h
For station No.2
E3h
to
RX7EF to RX7E0
15Eh
For station No.64
15Fh
RX7FF to RX7F0
The following tables show the station numbers and corresponding buffer-memory
addresses.
Table of station numbers and corresponding buffer memory addresses
Buffer
Station
Station
memory
number
number
address
1
E0
to E1
14
H
H
2
E2
to E3
15
H
H
3
E4
to E5
16
H
H
4
E6
to E7
17
H
H
5
E8
to E9
18
H
H
6
EA
to EB
19
H
H
7
EC
to ED
20
H
H
8
EE
to EF
21
H
H
9
F0
to F1
22
H
H
10
F2
to F3
23
H
H
11
F4
to F5
24
H
H
12
F6
to F7
25
H
H
13
F8
to F9
26
H
H
(a) Safety master station
remote device station
1) Safety master station
• The data input from safety remote I/O stations, standard remote I/O
stations and/or remote device stations are stored.
• An area of 2 words are allocated to each station. The refresh target CPU
devices are specified on the parameter setting screen of GX Developer.
For the setting details, refer to CHAPTER 6.
RX F to RX 0
RX1F to RX10
RX2F to RX20
RX3F to RX30
RX4F to RX40
to
Buffer
Station
memory
number
address
FA
to FB
27
H
H
FC
to FD
28
H
H
FE
to FF
29
H
H
100
to 101
30
H
H
102
to 103
31
H
H
104
to 105
32
H
H
106
to 107
33
H
H
108
to 109
34
H
H
10A
to 10B
35
H
H
10C
to 10D
36
H
H
10E
to 10F
37
H
H
110
to 111
38
H
H
112
to 113
39
H
H
8.2 Buffer Memory
8.2.2 Buffer memory details
Safety remote I/O station/standard remote I/O station/
Safety remote I/O station
(Station No.1, 1 occupied station)
X0F to X00
X1F to X10
Buffer
Station
memory
number
address
114
to 115
40
12E
H
H
116
to 117
41
130
H
H
118
to 119
42
132
H
H
11A
to 11B
43
134
H
H
11C
to 11D
44
136
H
H
11E
to 11F
45
138
H
H
120
to 121
46
13A
H
H
122
to 123
47
13C
H
H
124
to 125
48
13E
H
H
126
to 127
49
140
H
H
128
to 129
50
142
H
H
12A
to 12B
51
144
H
H
12C
to 12D
52
146
H
H
Standard remote I/O station
(Station No.2, 1 occupied station)
X0F to X00
X1F to X10
Buffer
Buffer
Station
memory
memory
number
address
address
to 12F
53
148
to 149
H
H
H
to 131
54
14A
to 14B
H
H
H
to 133
55
14C
to 14D
H
H
H
to 135
56
14E
to 14F
H
H
H
to 137
57
150
to 151
H
H
H
to 139
58
152
to 153
H
H
H
to 13B
59
154
to 155
H
H
H
to 13D
60
156
to 157
H
H
H
to 13F
61
158
to 159
H
H
H
to 141
62
15A
to 15B
H
H
H
to 143
63
15C
to 15D
H
H
H
to 145
64
15E
to 15F
H
H
H
to 147
---
---
H
H
1
2
3
4
5
6
H
H
H
H
7
H
H
H
H
H
H
8
H
H
8
- 8