Version-Up Method For Ic6203 (Cam_Sys P.c.board) - Panasonic DVCPRO AJ-CA901P Service Manual

Digital triax camera adapter/digital triax base station
Table of Contents

Advertisement

1-4-2. Version-up method for IC6203 (CAM_SYS P.C.Board)

1. Connect Flat cable (Included with VFK1304A) between connector P1 on VFK1304A and connector P6104 on
CAM_SYS P.C.Board.
2. Connect D-Sub Cable (9pin – 9pin: Cross type) between connector P2 on VFK1304A and COM1 port on PC.
3. Set SW201 [LOAD] on CAM_SYS P.C.Board to "ON" side.
4. Turn on the power of Camcorder and then boot up PC. (with DOS
5. Make a directory with any name on any hard drive (Ex. C:/ VSI1234) and then copy all files of version-up data
to there.
6. Type "Fl_all.bat" and hit Enter key.
7. When Progress bar reaches at the point of "100%", version upgrade is completed. (It takes about twenty-
minutes)
8. Turn off the power of camcorder and then set SW201 [LOAD] to original position.
PC
D-SUB 9pin-9pin
Cable
VFK1304
)
®
Camcorder
INS-7
P6104
ON
SW201
CAM_SYS P.C.B

Advertisement