9. G1000 System Return to Service Procedure
If a G1000 LRU was replaced, verify the correct LRU software part numbers and versions
against the numbers listed on the General Arrangement drawing listed in Table 1-1.
Perform the following subsection tests to confirm the G1000 system is operating correctly.
9.1
Display Test
Apply aircraft power. On the MFD power-up screen in the upper right corner, find the
'Beechcraft Gxx' number. The first line will indicate the airframe type. The number in
the second line is the G1000 System Loader Image version number that was used to
install the software to the system. (G58 image shown for reference, G36 is similar)
Verify that the System Software Version is the same as listed in Table 1 of the 005-
01474-02 General Arrangement Drawing.
Press the MFD ENT key to acknowledge the 'DEFAULT PROFILE' Crew Profile option
on the MFD (NOTE: The rightmost softkey may also be used).
G1000 NXi Supplemental Maintenance Manual
Textron Aviation G36/G58
Figure 9-1, MFD Power Up Page
Page 9-1
190-02765-05