information about enrolling Image Sensors remotely, see
To enroll the Image Sensor locally on a Simon XT:
Important: For smoothest installation, learn in one Image Sensor at a time. Insert batteries only after initiating learn
mode at the panel.
1. Begin with the batteries removed from the Image Sensor.
2. Put the panel into add mode using the keypad.
a. Go to the home screen.
b. Scroll to System Programming, then press [OK].
c. Enter the installer code (default is 4321), then press [OK].
d. Scroll to Interactive Services, then press [OK].
e. Scroll to Image Sensor Setup, then press [OK].
f. Scroll to Image Sensor Learn Mode, then press [OK]. The screen should display Power up or set I. S. Mode.
3. Insert the batteries into the Image Sensor. The LED on the Image Sensor progresses from blinking red to solid red
to blinking yellow. This indicates the Image Sensor is in learn mode.
4. Wait approximately 20 seconds for the Image Sensor to enroll to the panel. The screen on the panel displays the
following: I.S. [x] Added as Sensor [y]. The LED on the Image Sensor turns solid yellow indicating that it has
successfully found the panel.
5. After the Image Sensor LED has turned solid yellow, exit Add Mode on the panel. The Image Sensor LED
alternates between green and yellow while the customer's device list is updated with Alarm.com. The LED turns
solid green when the Image Sensor has been successfully added to the customer's account.
Note: If the Image Sensor is moved (tampered) after the LED has turned solid green, the Image Sensor enters test
mode for three minutes which is indicated by a red LED when motion is detected. Continue with the mounting
portion of the installation when in test mode. See the
6. After enrollment, be sure to keep the sensor and panel powered so the sensor can complete an initialization
process with the Alarm.com Network Operations Center. This process takes several minutes. Images cannot be
captured until initialization is complete. Check by verifying if the rules are confirmed on the Partner Portal or
MobileTech app.
The sensor is now learned into the panel. Sensors are enrolled in group 17 by default. To change the sensor group, use
the Sensors menu in Programming. Image Sensors may be enrolled in groups 15, 17, or 25. (No chime issued for group
25)
Note: Alarm.com does not recommend using sensor group 20 for Image Sensor Installations.
Installation: Mounting Image Sensor
1. Choose the desired location and mounting angle for the Image Sensor using the information in the chart. There are
three options:
https://answers.alarm.com/Partner/Installation_and_Troubleshooting/Image_Sensor/Image_Sensor_Version_3/Interlogix_Sim...
Enroll an Image Sensor on an Interlogix Simon
Image Sensor LED Reference Chart
XT.
for more details.
Updated: Fri, 10 Mar 2023 20:24:24 GMT
6

Advertisement

loading

This manual is also suitable for:

Simon xtiSimon xti-5Adc-is-300-lpSimon xt