Power Cycle
If you have issues connecting the Image Sensor to the account, power cycle the Image Sensor in one of two ways:
• Take out and reinsert the batteries, or
• Use a paperclip to quickly press and release the Sensor Reset button. Only press the reset button if the LED has
been off for at least 10 seconds and the panel is not in Add mode.
After a successful power cycle, the Image Sensor will enter the Sensor Power Up state (Blinking Red) followed by the
memory check state.
Network Reset
An Image Sensor must be network reset when it has been previously enrolled on a different panel. The Image Sensor
indicates that it is enrolled on a panel by blinking green after the memory check.
Important: A network reset only works if the Image Sensor is not actively communicating with a network. If the Image
Sensor is within range of the original panel, it is required that the Image Sensor first be deleted from the panel it was
previously learned into before being able to perform a network reset on the Image Sensor. See instructions on how to
properly delete the Image Sensor from the panel.
To perform a network reset:
1. Power up the Image Sensor.
2. Press and hold the reset button down with a narrow tool (such as a paperclip) for a full 10 seconds or until the red
LED flashes rapidly.
3. Release the reset button as soon as the red LED starts flashing rapidly. A successful network reset results in the
LED blinking yellow after the memory check. Panel association is now cleared from the Image Sensor's memory
and it should be available for enrollment.
After releasing the reset button, the Image Sensor enters sensor power-up mode (blinking red LED) followed by memory
check (solid red LED) followed by either a blinking green or blinking yellow light. For the full list of status indicators and
expected behaviors, see the Camera LED reference chart.