Other feature compatibility
Simon XT 2WTTS compatibility
When using a Two Way Talking Touchscreen with the Simon XT panel, Image Sensor activity is not reported or visible
on the touchscreen, except in alarms. When alarms are tripped on an enrolled Image Sensor, the alarms are reported
and displayed on the 2WTTS through the sensor 39 hardwire zone. Periodic activations on hardwire zone 39 appear on
the touchscreen as a result of the hardwire supervisions.
Two-Way Voice compatibility
Images cannot be transmitted while a Two-Way Voice call is in session. When the Image Sensor is installed on a
system with Two-Way Voice over the cellular network, image transmission during an alarm may be interrupted by the
two-way session. The image transmission resumes once the call has terminated.
Pet immunity settings
Two parts to making the Image Sensor pet immune:
1. Set PIR sensitivity settings to Low.
2. Mount set at a height of 6 feet, and install the sensor with the 6 degree mounting angle.
PIR activation and test mode
By default, the image sensor LED does not illuminate when activated by motion unless the sensor is in test mode. The
LED can be enabled by tampering the device or on the panel for each Image Sensor on a customer's account. The
Image Sensor must have successfully completed the enrollment process with a panel. When enabled, the red LED
illuminates for 3 seconds upon motion activations (at most every 3 minutes while disarmed).
To test the Image Sensor's PIR using the panel:
1. Scroll to System Programming, then press [OK].
2. Enter the installer code (default is 4321), then press [OK].
3. Scroll to Interactive Services, then press [OK].
4. Scroll to Image Sensor Setup, then press [OK].
5. Scroll to Image Sensor Settings, then press [OK].
6. Scroll to the I.S. Zone # to test, then press [OK].
7. Scroll to Test PIR, then press [OK]. The screen displays I.S. [y] in test for next 3 min to indicate the test mode
command has been sent.
Note: It may take up to 30 seconds for test mode to take effect after requesting Test PIR at the panel.
https://answers.alarm.com/Partner/Installation_and_Troubleshooting/Image_Sensor/Image_Sensor_Version_3/Interlogix_Sim...
Updated: Fri, 10 Mar 2023 20:24:24 GMT