Install alarm hardwire inside control panel
For Simon XT panels, connect the daughterboard alarm wire. When using the Simon XT panel, it is required to connect
the included blue alarm wire from the HW hardwire output located on the daughterboard (use HW, do not use C) to the
HW2 IN (terminal 3) slot on the Simon XT panel to enable local alarm activations.
Note: If using a module with firmware version 187+, the HW hardwire output is located on the Simon XT cellular module
to connect to the HW2 IN (terminal 3) slot on the Simon XT panel. Insert the blue alarm wire in the side where HW is
labeled.
Once an Image Sensor has been enrolled into the Simon XT panel, a hardwire zone is automatically programmed as
Sensor 39: ISHW. To ensure alarms are tripped properly on Image Sensors according to their enrolled group, the
hardwire sensor group is automatically configured. Do not alter the sensor group of Sensor 39 ISHW.
On the Simon XT, the panel screen displays Sensor 39: ISHW Alarm regardless of which Image Sensor tripped the
alarm. The Alarm.com Website and notifications, and the monitoring station report indicates the specific Image Sensor
that tripped the alarm.
Note: On the Simon XTi panel, the blue alarm hardwire is not required and should not be connected.