Design data alternator
Electrical power circuit
Model
Rated net output
Rating type (acc. ISO3046-7)
Coolant
Combustion system
Aspiration
Number of cylinders
Swept volume
Speed governing
Capacity of oil sump - initial fill
Capacity of cooling system
Electrical system
Emission Compliance
Maximum permissible load factor of PRP during 24h period
Standard
Make
Model
Rated output, class H temp. rise
Rating type (acc. ISO8528-3)
Degree of protection (IP index acc. NF EN 60-529)
Insulation class - stator
Insulation class - rotor
Number of wires
Circuit-breaker, 3ph
Number of poles
Thermal release It (thermal release is higher at 25°C)
Magnetic release Im
Circuit-breaker, 3ph - Lower voltage
Number of poles
Thermal release It
Magnetic release Im
- 79 -
D1703M-E4BG
13.2 kW
ICXN
coolant
indirect injection
natural aspirated
3
1.7 l
electronic
8 l
9 l
12 Vdc
EU Stage 5
100%
IEC 34-1/ISO 8528-3
Leroy Somer
LSA 40S3
15 kVA (3ph) - 10.5 kVA (1ph)
"BR" 125/40°C
23
H
H
12
4
20 A
3.5 x It
3
32 A
3.5 x It

Advertisement