Every 500 Hours Service - Komatsu D32E-1 Operation & Maintenance Manual

Bulldozer
Hide thumbs Also See for D32E-1:
Table of Contents

Advertisement

24. SERVICE PROCEDURE
24.7 EVERY 500 HOURS SERVICE
24.7.1 CHECK HOSE CLAMP TORQUE
REMARK
Check all hose clamps except those on the air intake system.
Check the torque. Refer to 21. STANDARD
TIGHTENING
TORQUES.
24.7.2 CHECK ROPS MOUNTING BOLT NUT TORQUE
Check the torque at four places.
w
Mounting Bolt Nuts:
822 f47 Nmm (605 f35 Ibf ft)
24.7.3 CHECK TRACK SHOE BOLT TORQUE
The bolts used for attaching the shoes to the tracks are heat treated alloy bolts
and will stand a considerable
tightening
strain. Ordinary bolts must not be
used. Nuts must be assembled so that washer face is not against track link.
Radius side of nuts must be against track link. Torque bolts to below listed
value.
a
Track shoe bolt:
90 220 N*m (65 +I5 Ibf ft) plus 120"
+
120" designates two flats of the bolt head.
24.7.4 INSPECT MOUNTED EQUIPMENT
Inspect for operational damage. Correct as required
24.7.5 RADIATOR
LEAKS
1.
Check for and correct any leaks at the radiator and its connecting
parts.
24.7.6 OUTSIDE OF RADIATOR CORE
1. Clean the outside of the radiator core.
3-41