m@ Using the Slot-type Charger
1
Plug the AC adapier cable into the adapter jack
located on the rear of the charger.
2 Plug the AC adapter into an AC wall outlet.
3
Slide the NiCd battery pack or the transceiver
equipped with the battery pack into the charging slot.
e
Confirm that the transceiver power is OFF.
e
Make sure that the metal contacts on the pack mate
securely with the charger terminals.
e
The indicator on the charger lights and charging starts.
Charging will take approximately 13 hours.
Indicator
4 After 13 hours, remove the battery pack or the
transceiver from the charging slot, or unplug the
charger from the AC wall outiet.
Note:
@
Repeatedly recharging a fully charged battery pack, or almost fully
charged pack, shortens its operating time. To resalve this problem,
use the pack until it is completely discharged.
Then recharge the
pack to full capacity.
*
if the operating time of a battery pack decreases although the battery
pack is fully and correctly charged, the battery pack life is over.
Replace the battery pack.
¢@
The provided slot-type charger cannot be used for an optional PB-37
NiCd battery pack.
@
When using the optional KSC-8A or KSC-14 charger, charging will
take the following amount of time (approx.):
PB-36
12 hours
1.5 hours
PB-37
18 hours
1.5 hours