Device Firmware Reboot; Resetting The Unit To Factory Settings - Cisco Fluidmesh 1200 VOLO Installation And Configuration Manual

Table of Contents

Advertisement

Fluidmesh 1200 VOLO
To do a 'hard' (device firmware) reboot under emergency conditions (for
example, if the unit malfunctions), do the steps in the following sub-
section.

Device firmware reboot

1.
Remove the bottom cover from the main unit enclosure as shown
in
"Connecting LAN cables to the unit" (page
2.
Insert a long tool with a thin shaft, such as a paper clip or a thin
screwdriver, into the RESET button port until the tool touches the
bottom
Figure 9. Fluidmesh 1200 VOLO (Hardware RESET button
port)
3.
Press the RESET button for one second, then release the button
immediately.
• The unit will reboot.

Resetting the unit to factory settings

The following methods are available to do a factory reset:
1. To do the reset using the configurator interface, refer to
the unit to factory defaults" (page
2. To do the reset using RACER, refer to the Fluidmesh Networks
RACER User Manual.
3. To do the reset by physically accessing the unit, follow the
procedure below.
© 2020 Cisco and/or its affiliates. All rights reserved.
(Figure 9 (page
33)).
CAUTION
Do not do a factory reset unless the unit needs to be
reconfigured using its factory configuration as a starting point.
A factory reset will reset the unit's IP address and administrator
password, and will disconnect the unit from the network.