Philips 107T60 Service Manual page 77

17" crt colour monitor
Hide thumbs Also See for 107T60:
Table of Contents

Advertisement

GENERAL PRODUCT SPECIFICATION
6.2
Display disturbances from external environment
6.2.1
ESD Disturbances
According to EN55024 (also refer to EN61000-4-2 for detail).
6.3
Display disturbances to external environment
The disturbances induced by the display and tolerated
by the environment are defined as follows
6.3.1
Ionizetic radiation
Completely fulfill International Commission of
Radio logical Protection (ICRP) requirement 0.5 mR/Hr.
Actually the set can reach 0.1 mR/Hr.
6.3.2
EMI/EMS
Can comply with FCC part 15,DOC C108.8 and EN55022 B Emission.
EN55024 Immunity; EN61000-3-2 Current Harmonics; EN61000-3-3 Flicker.
EMS EN61000-4-3 (80% 1KHz AM modulation) Picture jitter £ 2mm.
7.0
Safety tests
7.1
Dielectric strength (Hi-pot test)
According to IEC 60950, UL 1950 and CSA 22.2 No. 950
7.2
Resistance for protective earthing
According to IEC 60950
7.3
Leakage current
According to IEC 60950, UL 1950 and CSA22.2 No. 950
7.4
Grounding
According to IEC 60950, UL 1950 and CSA22.2 No. 950
8.0
Certifications
8.1
Safety
The monitors comply with the following safety standards:
- IEC 60950
- UL 1950
- DHHS 21 CFR, subchapter J
- CSA-22.2 NO. 950
- EK1-ITB 2000
8.2
EMI (Electromagnetic Interference)
The monitor comply with the following EMI standards :
- EN55022 B Emission
- FCC Part 15
-
DOC C108.8
17" V32 GS4 107T6-71K CMTR