76
107T6 CRT
Go to cover page
B-3 Transportation standards
(Test conditions: ambient temperature 20 - 23 degree C, relative humidity 40 - 65%)
Standards
Vibration test
Bump
test
Drop test
( cold drop
test)
Shock
test
2004-04-16
Wayne Lin
GENERAL PRODUCT SPECIFICATION
PCE All Regions Except China & India
PCE Standard
Sequence
7Hz, 1.05G
Amplitude(peak to peak): 10.6mm
Duration: 30 min.
1 axes (transport direction)
Result
Electrical function OK.
- Mechanical function OK.
- No serious damage in set
Parameter
No
Result
- Electrical function OK.
- Mechanical function OK.
- No serious damage in set
Height
42/25 cm (weight:15-16kg )
Sequence
Bottom(3 times): 42cm,
Left/Front/Right/Rear/Top: 25cm
( cold drop test: when applicable,
perform also the drop test with new
packaging after pre-condition for
16 hours at -10 C)
Result
- Electrical function OK.
- Mechanical function OK.
- No serious damage in set
For design evaluation only.
Half sine shock
: 100G, <3m sec. 6 shocks
: 23 C
Temp.
Humidity
: 60 %
Air pressure
:100kpa
Standard
: Mechanical Guideline
17" V32 GS4 107T6-71K CMTR
TYPE
:107T60/00
BRAND : PHILIPS
2004-04-16
PCE China & India
PCE Standard
a .10-30-10Hz. Amplitude: 19mm
Sweep: 5, Duration: 15 min.
3 axes (Refer to GB9384-97)
b. 30-55-10Hz. Amplitude: 6mm
Sweep: 5, Duration: 9min
3 axes (Refer to GB9384-97)
Acceleration: 100m/s2,
Pulse duration: 16ms,
Number of pulses: 1000,
Bump frequency:60-80 times/min.
(Refer to GB9384-97)
60/50 cm (weight:10-19kg )
6 face(bottom-front-left-rear-right)
3 edge( front-bot, right-bot, front-right)
Face : 60 cm
Edge/Corner: 50 cm
( cold drop test: pre-condition for
16 hours at -10 C)
8639 000 15483
31
21