Philips 107T60 Service Manual page 70

17" crt colour monitor
Hide thumbs Also See for 107T60:
Table of Contents

Advertisement

70
107T6 CRT
Go to cover page
Band I : 5 to 2K HZ.
Band II : 2K to 400K HZ.
Test procedure according to low emission and E.S.P. test method.
3.11
Display data channel : DDC2B (VESA STANDARD)
The DDC HEX Data (refer sheet 190) should be written into the
DDC IC (24LC21 or equivalent)
4.0
Display image (CRT facing east)
The monitor is aligned in a magnetic cage having the
following magnetic field components :
Northern Hemisphere : H = 0, V = 450 mG, Z = 0
Southern Hemisphere : H = 0, V = -500 mG, Z = 0
Conditions for visual testing, unless otherwise stated:
Input video signal
Brightness control
Contrast control
4.1
Display resolutions
See 3.1.3
4.2
Image size (For preset modes only)
The dimensions of guaranteed display area to be measured along the picture center of
horizontal and vertical axis of the screen as listed below: (preset modes only, refer
to fig. 1)
Width
Height
4.3
Image centering deviation (For preset modes only)
With respect to fig. 2, the target relationships are the following :
Note : This centering is adjustable by the end-user.
4.4
Picture shift control range (For preset modes only)
H-shift range : ± 10 mm min.
V-shift range : ± 10 mm min.
2004-04-16
Wayne Lin
GENERAL PRODUCT SPECIFICATION
Equatorial
: H = 0, V = 0 mG,
- 700 mVpp cross hatch
- center(50%)
- maximum(100%)
: 306 ± 3 mm
: 230 ± 3 mm
|A- B| £ 5 mm
|C- D| £ 5 mm
17" V32 GS4 107T6-71K CMTR
TYPE
:107T60/00
BRAND : PHILIPS
2004-04-16
Z = 0
8639 000 15483
31
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

107t60/00107t6

Table of Contents