Comelit People PL6721 Technical Manual
Hide thumbs Also See for People PL6721:

Advertisement

Quick Links

People
PL6721
F U L L T E C H N I C A L M A N U A L
Join us
in taking care
of our planet

Advertisement

Table of Contents
loading

Summary of Contents for Comelit People PL6721

  • Page 1 People PL6721 F U L L T E C H N I C A L M A N U A L Join us in taking care of our planet...
  • Page 2 | Table of contents | People door entry monitor art. PL6721 for Simplebus 2 system People series colour door entry monitor for Simplebus 2 system. Hands-free version with 4.3-inch / 16:9 screen. Even when switched off, the video door entry monitor can be programmed using a smartphone and the MyComelit app, which can be downloaded free of charge.
  • Page 3 | Table of contents | Table of contents Description Front buttons - factory programming Side buttons Indicator LEDs Technical specifications Programming the user code Programming the user code via the MyComelit app Programming the user code using the dip-switches Installation Disassembling the door entry monitor Removing and fitting the connection terminals Connections...
  • Page 4 | Table of contents | Description 1. 4.3’’ / 16:9 LCD screen. 2. Mechanical side buttons. 3. Mechanical front buttons, with touch guides for sight impaired users on the middle buttons of each row. 4. NFC detection area. 5. Microphone. 6.
  • Page 5 | Table of contents | Front buttons - factory programming Standard call to switchboard f Press the button to send a call to the porter switchboard. Generic actuator f Press the button to activate a generic actuator (art. 1256) or the relay for the external entrance panel.
  • Page 6: Side Buttons

    | Table of contents | Side buttons Button for activating “Silent mode” Confirm button Menu access and navigation button Buttons for scrolling menus and selecting values ACTIVATING “SILENT MODE” f Press the button to activate/deactivate Silent mode. » The red LED indicates that the function is active. ACCESSING AND NAVIGATING MENUS f Press one of the buttons below to access the user menu.
  • Page 7: Indicator Leds

    | Table of contents | Indicator LEDs Red LED Flashing: communication taking place. Flashing: incoming call/communication taking place. Flashing with door entry monitor in standby: “Door open” indication. White LED Lit steadily with door entry monitor in standby: “Automatic lock-release on receipt of call”...
  • Page 8: Technical Specifications

    | Table of contents | Technical specifications 135 mm 23 mm GENERAL DATA Product colour White RAL9003, Black RAL9005 Surface mounting Yes Desk base mounting Yes, with specific accessory Product weight 430 grams Coating material type ABS, PMMA COMPATIBLE SYSTEMS Simplebus 2 audio/video with power supply unit art.
  • Page 9: General Features

    | Table of contents | SETTINGS Loudspeaker volume Yes Ringtone volume Yes Screen brightness Yes Screen contrast Yes Screen colour Yes ENVIRONMENTAL AND CONFORMITY SPECIFICATIONS IP protection rating IP30 Operating temperature (°C) 5 ‐ 40 ° Operating humidity (max. RH) 25 - 75 % Environmental class I RoHS II - 2011/65/EU (EN IEC 63000:2018), EMC 2014/30/EU (EN 61000-6- CE certification...
  • Page 10 | Table of contents | Programming the user code A user code must be assigned to the door entry monitor. The user code can be programmed via the MyComelit app or using the dip-switches. << OR >> SOFTWARE VIA MYCOMELIT APP HARDWARE VIA DIP-SWITCH Programming the user code via the MyComelit app The door entry monitor has an NFC connection which means it can be programmed quickly and easily via the...
  • Page 11 | Table of contents | 3. Enter the desired user code and press “WRITE”. User code User code MyComelit user code user code user code WREITE WRITE Bring your smartphone close to the door entry monitor 4. Bring your smartphone close to the NFC detection area of the door entry monitor (identified by its label) and make a circular motion until you feel it vibrate.
  • Page 12 | Table of contents | if you want to program the user codes for other door entry monitors in sequence: 5.B Press "CONTINUE". Configuration complete! CONTINUA CONTINUE 6.B Select the desired increment interval. MyComelit MyComelit user code user code Select an increment* 7.B Bring your smartphone close to the NFC detection area of the new door entry monitor (identified by its label) and make a circular motion until you feel it vibrate.
  • Page 13 | Table of contents | Programming the user code using the dip-switches f Set the DIP-switches to ON to program a user code on the door entry monitor, as per Table of user codes. Example: code 4. TABLE OF USER CODES code DIP ON 1,2,3,4,5 1,3,4,5,6...
  • Page 14: Installation

    | Table of contents | Installation Fixing points for use when installing in compatible boxes CLACK...
  • Page 15 | Table of contents | Disassembling the door entry monitor Removing and fitting the connection terminals CLACK...
  • Page 16 | Table of contents | Connections PL6721 VIDEO ENTRY SYSTEM RISER CFP CFP 1214/2C 20 m max VIDEO ENTRY SYSTEM RISER CFP floor door call input Where multiple door-entry phones or door entry monitors have the same user code, connect the CFP button on one only;...
  • Page 17 | Table of contents | Programming The programmable buttons are supplied factory programmed with the following functions: [CCS] [ACTG] [AI] [AP] Standard call to Generic actuator Self activation Lock-release switchboard The programming of these buttons can be customised: • Using the MyComelit app via a smartphone •...
  • Page 18 | Table of contents | Programming via installer menu The function associated with the buttons can be changed via the installer menu. 1. Press one of the buttons below to access the user menu. 2. Press for 5 sec to access the installer menu. 5 sec »...
  • Page 19 | Table of contents | EXAMPLE: PROGRAMMING THE INTERCOM FUNCTION ON THE BUTTON 1. Press one of the buttons below to access the user menu. 2. Press for 5 sec to access the installer menu. » A confirmation tone will sound and the programming screen will appear.
  • Page 20 | Table of contents | Programming via MyComelit app √ Update the MyComelit App to the latest available version. The MyComelit app can be used to program the door entry monitor quickly and easily, even while it is switched off. The MyComelit app makes it possible to: •...
  • Page 21: Intercom Function

    | Table of contents | MAIN AND SECONDARY DOOR ENTRY MONITOR In systems with power supply unit art. 1210/1210A, one main door entry monitor and 3 secondary door entry monitors can be programmed for each apartment. In systems with power supply unit art. 4888C, 2 main door entry monitors and 2 secondary door entry monitors can be programmed for each apartment.
  • Page 22 | Table of contents | The maximum number of door entry monitors which can ring simultaneously nevertheless remains 3. 1. Program the intercom code on the door entry monitors you want to call. 2. On the desired button, program the “selective group intercom” function for the intercom codes of the door entry monitors you want to call.
  • Page 23 | Table of contents | Expansion diagrams PL6721 1216 CFP CFP 1214/2C 20 m max PL6721 PL6721 CFP CFP CFP CFP 1214/2C In systems with power supply unit art. 1210 or 1210A, a maximum of 1 main door entry monitor (P) and 3 secondary door entry monitors (S) can be programmed for each apartment.
  • Page 24: Wiring Diagrams

    1214/2C 1210A UT2020 A MAX B MAX C MAX E MAX H MAX Art. 1216 Comelit Art. 4577/4579 1 mm² 260 m 130 m 130 m 50 m (Ø 1.2 mm AWG 17) (850 feet) (425 feet) (425 feet) (164 feet) UTP5 cat.
  • Page 25: Basic Diagram

    | Table of contents | BASIC DIAGRAM 1216 PL6721 CFP CFP 1214/2C PL6721 CFP CFP 1214/2C 230V 1210A 1210 12 VAC/VDC 18 Ω MAX R GND NO NC UT2020 UT9200 (MAX 8) 20 m max. Local door-opener button.
  • Page 26 | Table of contents | DIGITAL ENTRANCE PANEL VARIANT WITH TOUCH-SCREEN MODULE ART. UT9270 Maximum 8O utenti 80 users massimo 1210A 1210 12 VAC/VDC 18 Ω MAX R GND NO NC UT2020 UT2010VC UT9270 Max 20 m. Local door-opener button. For systems with over 80 users, provide an additional power supply.
  • Page 27 1214/2C 4888C UT1020 1595 A MAX B MAX E MAX F MAX H MAX Art.1216 Comelit Art. 4577/4579 1 mm² 200 m 200 m 50 m 100 m (Ø 1.2 mm AWG 17) (650 feet) (650 feet) (165 feet) (330 feet) UTP5 cat.
  • Page 28 | Table of contents | BASIC DIAGRAM 1216 PL6721 CFP CFP 1214/2C PL6721 CFP CFP 1214/2C 2 3 4 4888C 230V 1595 120-230 V 12 VAC/VDC 18 Ω MAX NO NC UT1020 UT9200 (MAX 25) 20 m max. Local door-opener button.
  • Page 29 | Table of contents | Warning Intended use This Comelit product is designed and manufactured for use in the creation of audio and video communication systems in residential, commercial, industrial and public buildings. Installation All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with careful observation of the indications provided in the Manuals / Instruction sheets supplied with those products.
  • Page 30 C E R T I F I E D M A N A G E M E N T S Y S T E M S w w w . c o m e l i t g r o u p . c o m 1st edition 09/2023 Via Don Arrigoni, 5 - 24020 Rovetta (BG) - Italy code 2G40003123...

Table of Contents