4 INFORMATION ABOUT USE
4.1 Pre-start check
Important
•
Read carefully the following pages and carry out the operations described below in accordance with the
instructions specified.
•
Non compliance with the operations described in the following pages involves the risk of damages to the
engine and vehicle on which it is installed as well as personal and/or property damage.
•
Increase the frequency of maintenance operations in heavy working conditions (engine starts but stops, very
dusty and hot environments, etc...).
•
Check that the minimum required AdBlue®/DEF quantity is present inside the AdBlue®/DEF tank. Refer also
to the car documentation to check the AdBlue®/DEF level required for engine correct operation.
4.2 Running-in period
NOTE: For the first 50 hours of engine operation, it is advisable not to exceed 75% of the maximum power
supplied.
4.3 Starting and turning off
4.3.1 Starting
•
Check the level of the engine oil, fuel and coolant and fill if necessary (
•
Put the ignition key in the ignition switch (if supplied).
•
Tun the key to ON position.
•
Turn the key beyond the ON position and release it when the engine starts (the key will return into ON position
automatically).
Important
•
Do not actuate the starter for more than 15 seconds at a time. If the engine does not start, wait for one minute
before repeating attempt.
•
If engine does not start after two attempts see
4.3.2 After starting
Warning
•
Make sure that all the warning lights on the control panel are off when the engine is running.
•
Run at minimum speed for a few minutes according to table (except constant speed engine).
NOTE: To avoid damaging the engine do not use it mostly at idle for a long time ( MAX 30min. ).
≤ -20°C
from -20°C a -10°C
from -10°C a -5°C
from -5°C a 5°C
≥ 5°C
INFORMATION ABOUT USE
AMBIENT TEMPERATURE
Par. 4.5
Tab. 7.1 and Tab. 7.2
to found the cause.
4
e
Par. 4.6
).
TIME
2 minutes
1 minutes
30 seconds
20 seconds
15 seconds
33
EN