Specifications

Input Ratings / Characteristics

Nominal Input Voltage
Input Voltage Range
Nominal Input Frequency
Input Frequency Range
DC Input Voltage Range*
Input Current
Efficiency at 100% Load
Max Power Dissipation
Max Inrush Current (Cold Start)
Leakage Current
*Fulfills test conditions for this range. DC input safety approval can be obtained upon request.

Output Ratings / Characteristics**

Nominal Output Voltage
Factory Set Point Tolerance
Output Voltage Adjustment Range
Output Current
Output Power
Line Regulation
Load Regulation
PARD*** (20 MHz)
Rise Time
Start-up Time
Hold-up Time
Dynamic Response
(Overshoot & Undershoot O/P Voltage)
Start-up with Capacitive Loads
**For power de-rating from 50°C to 80°C, see power de-rating on page 3.
***PARD is measured with an AC coupling mode, 5 cm wires, and in parallel with 0.1 μF ceramic capacitor & 47 μF electrolytic capacitor.
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
2
www.DeltaPSU.com (June 2021, Rev. 08)
Arrow.com.
Arrow.com.
Downloaded from
Downloaded from
100-240 Vac
85-264 Vac
50-60 Hz
47-63 Hz
120-375 Vdc
< 1.50A @ 115 Vac, < 0.80A @ 230 Vac
> 89.0% @ 115 Vac & 230 Vac
0% load
< 0.4 W @ 115 Vac, < 0.9 W @ 230 Vac
100% load
< 7.4 W @ 115 Vac & 230 Vac
< 40 A @ 115 Vac, < 80 A @ 230 Vac
< 0.5 mA @ 240 Vac
24 Vdc
24 Vdc ± 2%
22-28 Vdc
2.50 A (60 W Max.)
60 W
< 0.5% (@ 85-264 Vac input, 100% load)
< 1.0% (@ 85-264 Vac input, 0-100% load)
< 240 mVpp
< 100 ms @ nominal input (100% load)
< 3,000 ms @ nominal input (100% load
> 20 ms @ 115 Vac,
> 125 ms @ 230 Vac (100% load
± 5% @ 85-264 Vac input, 0-100% load
(Slew Rate: 0.1 A/μs, 50% duty cycle @ 5 Hz to 1 KHz)
8,000 µF Max
)
)