20-drive configuration
16-drive configuration, plus the following:
Drive box 1 (six-bay HDD/two-bay NVMe Premium drive cage), connected to the 6 slot riser installed in the butterfly riser
cage.
Drive box 4 (universal media bay with two-bay SFF Premium drive cage), connected to the 6 slot riser installed in the
butterfly riser cage.
Or:
Drive box 1 (eight-bay NVMe SSD drive cage, with four NVMe drives installed), connected to the 6 slot riser installed in the
butterfly riser cage.

Six-bay SFF HDD/Two-bay NVMe SSD (Premium) drive cage cabling

CAUTION: To avoid damage to the cables and server components, always route cables flat against the server walls, and
separate the cables as they enter the primary riser cage. Bundled cables can be pinched or damaged when installing the
fan cage or primary riser cage.
The following images define supported cable routing pathways between the Six-bay SFF HDD/Two-bay NVMe SSD (Premium)
drive cage backplane and the riser cages. For more information on the supported configurations, see the NVMe drive cable
matrix.