Remove the processor mezzanine tray (Removing and replacing the processor mezzanine tray).
Remove the CPU Mezzanine UPI performance kit (Removing and replacing a CPU Mezzanine UPI performance kit
board).
10. Remove the fan cage (Removing and replacing the fan cage).
11. To remove or reroute cables, remove the fan cage holders (Removing and replacing the fan cage holders).
12. Disconnect the cables from the drive cage backplane.
13. Remove the drive cage.
To replace the component, reverse the removal procedure.

Removing and replacing an eight-bay NVMe SSD drive cage

Procedure
1.
Power down the server.
2.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3.
Do one of the following:
Extend the server from the rack (Extending the server from the rack).
Remove the server from the rack (Removing the server from the rack).
4.
Remove the access panel (Removing the access panel).
62