2-3. Replacement of Master Black Control
(RCP-730)
Disconnecting
1. Remove the screw to remove cover tube.
Precision
+P2.6 x 6
2. Unscrew cover fixed shaft. Remove the screw
to remove adjustment tube.
Cover fixed
shaft
Adjustment
tube
RCP-730
RCP-731
3. Remove the nut securing the control and remove the
Cover tube
4. Desolder harness connected to the control.
Setscrew
2.6 x 3
2-3. Replacement of Master Black Control (RCP-730)
two screws. VR fixed tube will be removed.
Setscrew
2.6 x 3
VR fixed tube
2-3 (E)