Chapter 4
[HA210] to [HA234]
2nd motor When Intelligent Input terminal 024[SET] is enabled.
Code/Name
HA210
Stabilization constant, 2nd-motor
HA215
Speed response, 2nd-motor
HA220
ASR gain switching mode selection,
2nd-motor
HA221
ASR gain switching time setting,
2nd-motor
HA222
ASR gain mapping intermediate
speed 1, 2nd-motor
HA223
ASR gain mapping intermediate
speed 2, 2nd-motor
HA224
ASR gain mapping maximum speed,
2nd-motor
HA225
ASR gain mapping P-gain 1,
2nd-motor
HA226
ASR gain mapping I-gain 1,
2nd-motor
HA227
ASR gain mapping P control P-gain 1,
2nd-motor
HA228
ASR gain mapping P-gain 2,
2nd-motor
HA229
ASR gain mapping I-gain 2,
2nd-motor
HA230
ASR gain mapping P control P-gain 2,
2nd-motor
HA231
ASR gain mapping P-gain 3,
2nd-motor
HA232
ASR gain mapping I-gain 3,
2nd-motor
HA233
ASR gain mapping P-gain 4,
2nd-motor
HA234
ASR gain mapping I-gain 4,
2nd-motor
Basic parameters for Induction motor
Code/Name
Range
Initial
(unit)
value
Hb102
Same as HA110
Motor capacity
setting, 1st-motor
Same as HA115
Hb103
Motor number of
Same as HA120
poles setting,
1st-motor
Same as HA121
Hb104
Motor base
Same as HA122
frequency setting,
1st-motor
Same as HA123
Hb105
Motor maximum
frequency setting,
Same as HA124
1st-motor
Hb106
Same as HA125
Motor rated
voltage, 1st-motor
Same as HA126
Hb108
Motor rated
Same as HA127
current, 1st-motor
・If the motor capacity [Hb102] and number of poles
Same as HA128
[Hb103] are changed, the motor characteristics are set
according to the internal Hitachi table values.
・The output is decided by setting the frequency and
Same as HA129
voltage. Below there is an example of V/f control.
Same as HA130
Same as HA131
Same as HA132
Same as HA133
Same as HA134
・By setting the motor rated current, a reference current
for the motor protection is set.
※Initial value depends on the inverter.
Motor typical data
Number of poles
4-43
For parameter configuration
[Hb102] to [Hb108]
Range (unit)
0.01 to
Async.
160.00 (kW)
Async.
2 to 48 (Pole)
Async.
10.00 to
[Hb105] (Hz)
Async.
[Hb104] to
590.00 (Hz)
Async.
1 to 1000 (V)
Async.
0.01 to
10000.00 (A)
Output
voltage
Motor rated
voltage
(Ex.)400V
Base frequency
(Eg.)50Hz
Code
Capacity
[Hb102]
[Hb103]
[Hb104]
Frequency
[Hb105]
Voltage
[Hb106]
Current
[Hb108]
Initial value
Motor capacity setting
4P
60.00(JPN)(USA)/
50.00(EU)(ASIA)(CHN)
60.00(JPN)(USA)/
50.00(EU)(ASIA)(CHN)
(400V Class)
400(JPN)(EU)(ASIA)(CHN)
460(USA)
Motor capacity setting
frequency
reference (Hz)
Maximum
frequency
Range of values (Unit)
0.01 to 160.00 (kW)
2 to 48 (poles)
10.00 to 590.00 (Hz)
10.00 to 590.00 (Hz)
1 to 1000 (V)
0.01 to 10000.00 (A)