Hitachi LH1 Series Basic Manual page 50

Table of Contents

Advertisement

Chapter 4
[AA111] to [AA115][bb-40]
RUN command selection
Code/Name
00([FW]/[RV] terminal)
AA111
01(3-wire)
02(Keypad's RUN-key)
RUN command
03(RS485)
input source
04(Option-1)
selection,
05(Option-2)
1st-motor
06(Option-3)
・Select in which way will be operated.
In case it does not work, please review it.
Keypad keys setting
Code/Name
AA-12
RUN-key
00(Forward)/
command rotation
01(Reverse)
direction
AA-13
00(Disable)/01(Enable)/
02(Enable at only trip reset)
STOP-key enable
・[AA-12] specifies in which direction (forward/reverse)
will be the rotation after pressing the RUN key in the
operation keypad.
[AA-13] changes the behavior of the STOP key of
keypad. When 01 (enable) (initial value) is set, the
STOP key performs stop operation regardless of the
run command selection. When stopping only with the
command selected in the run command selection,
change it to 00(disabled). If the run command selectin
[AA111] is set to 02(Keypad's RUN key), the STOP key
on the Keypad is valid regardless of the [AA-13]
setting.
RUN command direction restriction
Code/Name
AA114
RUN direction
restriction,1st-motor
・ In the case of an incorrect RUN command, [AA114] setting
prevents the output from unintended rotation.
Restart operation after decel/free-run STOP
Code/Name
AA115
00(Deceleration stop)/
STOP mode
01(Free-run stop)
selection, 1st-motor
00(Restart at 0Hz)/
01(Restart with matching
bb-40
Restart mode after FRS
02(Restart with active
release
frequency matching)/
03(Detect speed) *1)
*1) Requires encoder feedback to the P1-FB option or the input terminal
function 103[PLA]/104[PLB] assigned [A]/[B] terminals.
In [AA115] setting, deceleration stop or free-run stop
can be selected when a stop command is executed.
・If input terminal 032[FRS] is active (ON), free-run stop is
possible.
・With [bb-40], a restart with the release of the [FRS], or a
restart operation that will be executed after the
free-run-stop operation will be selected.
・If it selected free-run-stop (the torque will be lost), it can
be configured to stop by inertia in case of the [E007]
overvoltage error occurs during deceleration.
Range (unit)
Initial value
02(JPN)/
00(EU)
(USA)
(ASIA)
(CHN)
Range (unit)
Initial value
00
01
Range (unit)
Initial value
00(No restriction)/
01(Only forward)/
00
02(Only reverse)
Range (unit)
Initial value
00
frequency)/
00
For parameter configuration
Control mode selection
Code/Name
00 ([V/f] Fixed torque characteristics (IM))/
01 ([V/f] Reducing torque characteristics (IM))/
02 ([V/f] Free V/f (IM))/
03 ([V/f] Auto torque boost (IM))/
04 ([V/f with encoder]
Fixed torque characteristics (IM)/
05 ([V/f with encoder]
AA121
Reduced torque characteristics (IM)/
Control
06 ([V/f with encoder] Free V/f (IM)/
mode
07 ([V/f with encoder] Auto torque boost (IM)/
selection,
08 (Sensorless vector control (SLV) (IM))/
1st-motor
09 (0Hz-range sensorless vector control
(0Hz-SLV) (IM)) / *1)
10 (Vector control with encoder (CLV)(IM)) /
11(Synchronous start type
sensorless vector control(SM/PMM))/
12 (IVMS start type sensorless vector control
(SM/PMM)) *1)
・Generally for a light duty control (such as fans or pumps) , the
[V/f] control with fixed torque characteristics or the [V/f]
control with reducing torque characteristics similar to the
operation characteristics of fans and pumps is selected.
・For a magnet motor, select the sensorless vector control
(SM/PMM).
*1) The setting (09/10/12) is not suitable for LH1 series.
Vector control with encoder mode
Code/Name
AA123
00(Speed/Torque control mode)/
01(Pulse train position control)/
Vector control
02(Position control)/
mode selection,
03(High-resolution position control)
1st-motor
・Torque control is effective only when the AA121 setting is 08 to
12 and the AA123 settting is 00.
・Pulse train position control is effective only when the AA121
setting is 10 and the AA123 setting is 01, And input trminal
073[STAT] is assignd and must be ON.
・Absolute position control is effective only when the AA121
setting is 10 and the AA123 setting is 02 or 03.
・For more information, contact to your supplier or local Hitachi
distributor or service station.
2nd motor When Intelligent Input terminal 024[SET] is enabled.
Code/Name
AA201 Main speed input source selection,
nd-motor
AA202 Sub speed input source selection,
2nd-motor
AA204 Sub speed setting, 2nd-motor
AA205 Speed reference calculation symbol
selection, 2nd-motor
AA206 Add frequency setting, 2nd-motor
AA211 RUN command input source selection,
2nd-motor
AA214 RUN-direction restriction selection,
2nd-motor
AA215 STOP mode selection, 2nd-motor
AA221 Control mode selection 2nd-motor
AA223 Vector control mode selection, 2nd-motor
4-10
[AA121] to [AA223]
Range (unit)
*1)
Range (unit)
Initial value
00
Range
(unit)
Same as AA101
Same as AA102
Same as AA104
Same as AA105
Same as AA106
Same as AA111
Same as AA114
Same as AA115
Same as AA121
Same as AA123
Initial
value
00
Initial
value