Mode 2 Bidirectional Timing

Name
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
E Series User Manual
(NI 6016 and NI 6025E Devices Only)
specifications for a bidirectional transfer in mode 2.
WR *
OBF *
INTR
ACK *
STB *
IBF
RD *
DATA
Figure 4-5. Bidirectional Transfer Timing Specifications
Table 4-5. Bidirectional Transfer Timing Specification
Description
WR* = 1 to OBF* = 0
Data before STB* = 1
STB* Pulse Width
STB* = 0 to IBF = 1
Data after STB* = 1
ACK* = 0 to OBF* = 1
ACK* Pulse Width
ACK* = 0 to Output
ACK* = 1 to Output Float
RD* = 1 to IBF = 0
Figure 4-5 and Table 4-5 show timing
T1
T3
T4
T2
T5
Minimum (ns)
20
100
50
100
20
4-8
T6
T7
T10
T8
T9
Maximum (ns)
150
150
150
150
250
150