Pxi E Series Devices - National Instruments PXI-6031E User Manual

Daq
Table of Contents

Advertisement

Chapter 8
Real-Time System Integration Bus (RTSI)
Note
In NI-DAQmx, you can indirectly route timing signals not shown in the above
diagrams to RTSI. For a detailed description of which routes are possible on your device,
in MAX, select Devices and Interfaces, your device, then select the Device Routes tab.

PXI E Series Devices

E Series User Manual
Trigger <0..6>
RTSI Trigger 7
Figure 8-1. PCI E Series Signal Connection Scheme
Refer to the
Timing Signal Routing
for a description of the signals shown in Figure 8-1.
The RTSI trigger lines connect to other devices through the PXI bus on the
PXI backplane. RTSI <0..5> connect to PXI Trigger <0..5>, respectively.
This signal connection scheme is shown in Figure 8-2. The RTSI Clock is
connected to PXI Trigger 7. In PXI, RTSI 6 connects to the PXI star trigger
line, allowing the device to receive triggers from any star trigger controller
DAQ-STC
Switch
section of Chapter 7,
8-2
ai/ConvertClock
ai/StartTrigger
ai/ReferenceTrigger
ao/SampleClock
ao/StartTrigger
Ctr0Source
Ctr0Gate
Ctr0InternalOutput
Ctr0Out
ai/SampleClock
ai/PauseTrigger
ai/SampleClockTimebase
ao/SampleClockTimebase
Ctr1Source
Ctr1Gate
ao/PauseTrigger
20MHz Timebase
Master Timebase
Digital
Routing,
ni.com