8.2 Character String Instructions
Processing
Example 1) When a string "ABC1230 DEF" (11 characters including a space) is to be
converted
S1...K12 S2... "ABC1230 DEF" D...DT0
(Note 1)
Data outside the range in the destination (*) (bytes higher than DT7) does not change.
(1)
Storage area size
Example 2) With the 16 characters from A to P as one set, when 16 sets (256
characters in total) are to be repeatedly converted
S1...K256 S2... "ABCDEF...KLMNOP" D...DT0
(1)
Storage area size
Example 3) A string of zero character bracketed by "" (i.e. double quotation marks in
sequel) is converted
S1...K1  S2... ""  D...DT0
(Note 1)
Data outside the range in the destination (*) (DT2 to DT7) does not change.
8-20
(2)
Number of characters
(2)
Number of characters