Section 4 • Repair Procedures

Platform Components

1-1

Platform

How to Remove the Platform
1 Tag and disconnect the taillight control cable at
the front of the platform.
2 Remove the platform rotate handle (if equipped).
3 Support and secure the platform to an
appropriate lifting device. Do not apply any
lifting pressure.
4 Remove the fasteners securing the platform to
the platform mount bracket.
5 Remove the pin securing the platform to the
platform rotator assembly.
Crushing hazard. The platform
could become unbalanced and fall
if not properly supported when the
pin is removed.
6 Remove the platform from the platform rotator
assembly.
4 - 2
1-2

Platform Rotator (if equipped)

The platform rotator is a manually-operated gear
assembly used to rotate the platform.
How to Remove the
Platform Rotator
1 Remove the platform. See 1-1,
How to Remove the Platform .
2 Tag and disconnect the platform control cable(s)
from the platform controls.
3 Tag and disconnect the wiring at the power-to-
platform junction box on the platform rotator
assembly.
4 Completely loosen the shaft retaining fasteners
at the bottom of the platform pivot shaft.
Remove the platform rotate assembly from the
machine.
Genie TZ-34/20