Platform
How to Remove the Platform
1
Separate the foot switch quick disconnect
plug.
2
Support the platform with an appropriate
lifting device.
3
Locate the cables that connect to the bottom
of the control box. Number each cable and its
location at the platform control box.
4
Disconnect the cables from the bottom of the
platform control box.
5
Remove the platform control box mounting
fasteners. Remove the platform control box
and set it aside.
6
Remove the air line to platform bracket
retaining fasteners (if equipped).
7
Remove the power to platform cover plate
from the electrical outlet box. Do not
disconnect the wiring.
Electrocution/burn hazard.
Contact with electrically charged
circuits could result in death or
serious injury. Remove all rings,
watches and other jewelry.
8
Remove the power to platform electrical outlet
box from the platform and lay it to the side.
28
9
10
11
12
SX™-105 XC™ • SX™-125 XC™
Remove the weld cable from the platform (if
equipped).
Electrocution/burn hazard.
Contact with electrically charged
circuits could result in death or
serious injury. Remove all rings,
watches and other jewelry.
Support the platform mounting weldment, but
do not apply any lifting pressure.
Remove the eight mounting bolts from the
platform mounting weldment.
Remove the center bolt and slide the platform
mounting weldment off of the platform rotator.
Crushing hazard. The platform
mounting weldment may
become unbalanced and fall if it
is not properly supported.