Case Specifications; Condensing Unit Data - Hussmann RED Installation And Operation Manual

Refrigerated end display
Hide thumbs Also See for RED:
Table of Contents

Advertisement

IGUP-RED-0309
Model
Refrigeration
&
Btu / Hr.
Length
(Ft.)
(Total)
Evap. Prod. Disch.
4'
1,700 6,800
20°
6'
1,700 10,200
20°
8'
1,700 13,600
20°
12'
1,700 20,400
20°
Set (PSI)
Out
4'
30
6'
30
8'
2 Units
30
12'
2 Units
30
Average
Disch. Air T~Stat
Temperatures (°F) Speed Settings Type
(CFM)
34°
28°
300
34°
28°
300
34°
28°
300
34°
28°
300

Condensing Unit Data

Size
Voltage
In
(HP)
(VAC)
50
1
208 ~ 230
1
50
1
/
208 ~ 230
2
50
1
208 ~ 230
1
50
1
/
208 ~ 230
2

Case Specifications

Coil
Fan Blade
Size (in) & Evap. per day
(°F)
Pitch ( ° )
28°
Forced
8" x 30°
Air
28°
Forced
8" x 30°
Air
28°
Forced
8" x 30°
Air
28°
Forced
8" x 30°
Air
Ampacity
13.0
19.0
13.0 ea.
19.0 ea.
8
Qty.
Defrosts
Elec. Load (Amps) @ ~115 VAC
Fans
Fans
Min. Qty.
Eng. Eff.
1
20
4
0.33
2
20
4
0.66
2
20
4
0.66
3
20
4
0.99
Fans Case
Shelf
Std. Lights Levels
0.60
3.6
4
1.20
3.6
4
1.20
6.04
4
1.80
8.48
4

Advertisement