H H e e a a t t e e r r A A t t t t r r i i b b u u t t e e D D a a t t a a
BAYEABC15BK1 - Circuit 1
(a)
BAYEABC15BK1 - Circuit 2
BAYEABC20BK1 - Circuit 1
BAYEABC20BK1 - Circuit 2
Note: ** Motor Amps
MCA and MOP for circuit 1 contains the motor amps
(a)
Heater Model No.
No Heater
BAYEAAC04++1
BAYEAAC05++1
BAYEAAC08++1
BAYEAAC10++1
BAYEAAC10LG3
BAYEABC15LG3
BAYEABC15BK1 - Circuit 1
(a)
BAYEABC15BK1 - Circuit 2
BAYEABC20BK1 - Circuit 1
BAYEABC20BK1 - Circuit 2
Note: ** Motor Amps
(a)
MCA and MOP for circuit 1 contains the motor amps
Heater Model No.
No Heater
BAYEAAC04++1
BAYEAAC05++1
BAYEAAC08++1
BAYEAAC10++1
BAYEAAC10LG3
BAYEABC15LG3
BAYEABC15BK1 - Circuit 1
(a)
BAYEABC15BK1 - Circuit 2
BAYEABC20BK1 - Circuit 1
BAYEABC20BK1 - Circuit 2
BAYEACC25BK1 — Circuit 1
BAYEACC25BK1 — Circuit 2
BAYEACC25BK1 — Circuit 3
Note: ** Motor Amps
MCA and MOP for circuit 1 contains the motor amps
(a)
52
TAMXB0C36V31DB
9.60
32800
2
4.80
16400
9.60
32800
2
9.60
32800
TAMXB0C42V41DB
No. of
Capacity
Circuits
Amps per
kW
BTUH
0
-
-
1
3.84
13100
1
4.80
16400
1
7.68
26200
1
9.60
32800
1-3 PH
9.60
32800
1-3 PH
14.40
42000
9.60
32800
2
4.80
16400
9.60
32800
2
9.60
32800
TAMXB0C48V41DB
No. of
Capacity
Circuits
Amps per
kW
BTUH
0
-
-
1
3.84
13100
1
4.80
16400
1
7.68
26200
1
9.60
32800
1-3 PH
9.60
32800
1-3 PH
14.40
42000
9.60
32800
2
4.80
16400
9.60
32800
2
9.60
32800
9.60
32800
3
9.60
32800
4.80
16400
40.0
55
60
20.0
25
25
40.0
55
60
40.0
50
50
240 Volt
Minimum
Heater
Maximum
Circuit
Overload
Ampacity
Circuit
Protection
4.1 **
5
15
16.0
25
25
20.0
30
30
32.0
45
45
40.0
55
60
23.1
34
35
34.6
48
50
40.0
55
60
20.0
25
25
40.0
55
60
40.0
50
50
240 Volt
Minimum
Heater
Maximum
Circuit
Overload
Ampacity
Circuit
Protection
6.1 **
8
15
16.0
28
30
20.0
33
35
32.0
48
50
40.0
58
60
23.1
37
40
34.6
51
60
40.0
58
60
20.0
25
25
40.0
58
60
40.0
50
50
40.0
58
60
40.0
50
50
20.0
25
25
7.20
24600
34.6
3.60
12300
17.3
7.20
24600
34.6
7.20
24600
34.6
208 Volt
Heater
Capacity
Amps per
kW
BTUH
Circuit
-
-
4.1 **
2.88
9800
13.8
3.60
12300
17.3
5.76
19700
27.7
7.20
24600
34.6
7.20
24600
20.0
10.80
36900
30.0
7.20
24600
34.6
3.60
12300
17.3
7.20
24600
34.6
7.20
24600
34.6
208 Volt
Minimum
Heater
Capacity
Amps per
kW
BTUH
Ampacity
Circuit
-
-
6.1 **
2.88
9800
13.8
3.60
12300
17.3
5.76
19700
27.7
7.20
24600
34.6
7.20
24600
20.0
10.80
36900
30.0
7.20
24600
34.6
3.60
12300
17.3
7.20
24600
34.6
7.20
24600
34.6
7.20
24600
34.6
7.20
24600
34.6
3.60
12300
17.3
48
50
22
25
48
50
43
45
Minimum
Maximum
Circuit
Overload
Ampacity
Protection
5
15
22
25
27
30
40
40
48
50
30
30
43
45
48
50
22
25
48
50
43
45
Maximum
Circuit
Overload
Protection
8
15
25
25
29
30
42
45
51
60
33
35
45
45
51
60
22
25
51
60
43
45
51
60
43
45
22
25