Trane TAMXB0A24V21DB Installation, Operation And Maintenance Manual page 35

Variable speed air handlers convertible 2 - 5 ton
Table of Contents

Advertisement

Table 19. Link Communicating Low Voltage Wire Connectors
Link mode uses simple connectors for low voltage connections. These
connections are color coded which makes the installation easier and
quicker.
Wire Colors
R
DH
DL
B
Do the following to make the connections from the actual thermostat
wire to the connector.
Note: These connectors are necessary at the communicating outdoor
unit, communicating indoor unit, distribution board(s), system
controller and communicating accessories.
1.
Strip the Red, White, Green and Blue thermostat wires back 1/4".
2.
Insert the wires into the connector in the correctly colored
locations.
3.
When you feel it release, allow each wire to slide in
further.
4.
Pull back on the wires individually and slightly and check if the
wires are seated properly. If each wire does not pull out for all four
wires, the connection is complete.
5.
Connectors are ONE TIME USE. If a 18 ga. Thermostat wire gets
broken off inside of the connector, the connector will need
replaced.
6.
Wire colors are for illustration purposes only. If using a different
color, ensure it lands at the correct terminal throughout all of the
communicating control wiring.
Connect the CAN connector into the male coupling on the low voltage
harness at the Outdoor unit.
This air handler has two dedicated CAN Connector headers on the Air
Handler Control (AHC) board. In Link communicating mode, both of
them are in the communicating loop. It does not matter which one
goes to the thermostat, System Controller, distribution board, outdoor
unit or any other Link accessory.
18-GJ89D1-1F-EN
Red
White
Green
Blue
Note: For use with 18 ga. solid core thermostat wire.
Note: Note: For connections to the AHC, do not add color-coded
E E l l e e c c t t r r i i c c a a l l — — L L o o w w V V o o l l t t a a g g e e
CAN Connector
Strip the control
wire back- 1/4"
connectors to the thermostat wire until after it has been pulled
inside the blower compartment. (The CAN connector will not fit
through the 1/2" drilled hole.)