<Note>
Do not use any fuel other than the specified light oil type. Doing so may lead to the
problems described below.
• This machine complies with the exhaust gas regulations. If you use any type of
fuel other than the specified light oil type, the machine will be a product not
conforming to the exhaust gas regulations.
• Using fuel mixed with heavy oil, kerosene or alcohol, or degraded fuel may have
negative effect on the machine functions (a decrease in output, start-up
performance deterioration) or cause the engine to malfunction (component wear
and corrosion, early deterioration of the engine oil, fuel filters or fuel hoses).

7-4. Inspection for Fuel/Oil/Cooling Water Leakage

Warning: Fire
• Absolutely never use the equipment if there is a fuel, oil or cooling water leak,
and be sure to always repair the leak before using.
Open the side door and check for fuel leakage from fuel line joints and similar
components, and check for oil and cooling water leakage. Open the fuel tap to
perform inspection and close it after inspection has been completed.

7-5. Battery Inspection

Warning: Injury to Eyes and Skin
• Use protective gear, such as rubber gloves, when inspecting or replacing the
battery due to the dilute sulfuric acid in the battery fluid. Be sure that fluid does
not get into eyes, or on skin or clothing.
• If battery fluid gets into the eyes, or on the skin or clothing, immediately wash
with a large amount of water, and always be especially sure to seek medical
attention if it gets into the eyes.
Warning: Explosion
• Do not operate the equipment or recharge the battery when the battery fluid level
is below the lower level.
• Do not generate any sparks near the battery and do not allow any fire or other
open flame near the equipment because the battery generates ignitable gas.
1)
Inspect the battery fluid level. If it is
near the lower level, add distilled
water until it reaches the upper level.
2)
Inspect for loose terminals and
retighten if loose.
<Note>
• It is necessary to recharge the battery when the specific gravity of the battery
fluid is 1.23 or less. Contact the retail outlet where the equipment was purchased
if this occurs.
Terminal
- 15 -
UPPER
LEVEL
LOWER
LEVEL