3.3

How to Enter the Initial Settings

After you set the purpose of the radar, enter the initial settings as follows.
1. On the main menu, press
Target
ARPA
AIS
GPS
System
Initial
Tests
Sector Blank **
Units
Installation
Factory
2. Press the ENTER key. The Installation menu becomes active and the cursor moves to the
right column.
3. Press
or
to select an item from the [Installation] menu.
4. Press the ENTER key to show the setting window.
5. Press
or
to select an option.
6. Press the ENTER key to validate the setting.
7. Press the MENU key to close the main menu.
Basic Settings
Input Source: Select the input source from [Master] and [Slave]. The default setting is [Master].
Master: A display unit operates as the main radar.
Slave: A display unit operates as a remote display. For the remote display, make sure you
adjust the [Video Init Adjust] and [Timing Adjust] (page 3-5 and 3-6).
ARPA QV Select: Set to [On] position to display quantized video on the screen. Set to [Off] posi-
tion for normal use.
Demo Mode: Set to [On] position to activate the demo mode. Set to [Off] position for normal use.
or
to select [Installation].
Menu
Menu
Input Source
ARPA QV Select
Demo Mode
Antenna Rotation
Antenna Height
Near STC Level
A/C Auto Adjust
Heading Adjust
Timing Adjust
MBS Adjust*
Video Init Adjust*
ARPA Adjust SP*
ARPA Adjust MP*
ARPA Adjust LP*
Auto Install Setup*
Total On Time*
Total TX Time*
Memory Clear*
[ENTER]: Enter [CANCEL/HL OFF]: Back
[MENU]: Exit
* : Displayed when scrolled.
** : Set the [Sector Blank] to [Off] in order to
Installation
Installation
: Master
: Off
: Off
: Rotate
: 15m
: 2
: 0
: 0. 0 °
: 0.000 NM
: 0
: 6
: 2
: 2
: 2
: 000000.5 h
: 000000.6 h
execute [Auto Installation Setup] in the
[Installation] menu.
3-3