3.11.5 Self cleaning mode

Self cleaning mode will reduce the growth of mold fungus with
plasmacluster ions and dry the inside of the unit. Utilize this mode at
seasonal change over terms.
▶ Press the Clean button when the unit is not operating.
The remote control displays
The blue plasmacluster lamp on the unit turns on.
The unit stops operation after 90 minutes.
To cancel self cleaning mode:
▶ Press the Stop button.
The blue plasmacluster lamp on the unit turns off.
Temperature, fan speed, airflow direction or timer can not be set during
self cleaning mode.
Mold fungus already grown can not be eliminated by this operation.

3.11.6 Movement sensor

▶ Press the Eco key during automatic mode, to activate the movement
sensor ( Fig. 1, [6]).
The indoor unit is intelligently controlled, depending on the presence
or absence of persons and the amount of movement in the room.
• Function with low activity: if the sensor detects no movement in the
room for 60 minutes, the air conditioning system reduces the output.
As soon as movement is detected in the room once again the output
increases to the normal value.
• Function with increased activity: if the detected activity level
increases, the set temperature falls. The fan speed also increases in
Cooling mode. If automatic vertical Swing mode is set, the airflow
direction will be set obliquely downward.
If the movement sensor fails to detect a person, this could be caused by
the following:
• There is no movement for long periods of time (for example a person
sleeping, little baby, unable to move because of injury or illness).
• Only a small area of skin is exposed (for example being covered with
a quilt, wearing thick clothes, pointing the back to the air
conditioner).
• Movements are concealed by furniture.
• The temperature difference between the room and the person's body
is small (room temperature above 30 °C.)
If the movement sensor incorrectly detects one or more persons, this
could be caused by the following:
• There are small animals such as cats and dogs moving around.
• There is too much sunshine or warm wind entering the room.
• There is an object with high temperature in the room such as a heater.
• The room temperature changes a lot in a short time.

3.11.7 Changing the brightness of the lamps

When the lamps on the unit are too bright:
▶ During operation, press the Display button.
The plasmacluster lamp on the unit turns off.
The other lamps become dark.
To light up the lamps:
▶ Press the Display button again.
Climate Class 6000i/8000i – 6721831490 (2022/11)
for 1 minute.

3.11.8 Auxiliary mode

Use this mode when the remote control is not available.
To turn on:
▶ Press the ON/OFF button ( Fig. 1, [5]).
The ON indicator K lights up and the appliance starts in automatic
mode. Fan speed and temperature are set to auto mode.
To turn off:
▶ Press the ON/OFF button again.
The ON indicator K turns off.
3.12

Additional notes on operation

Operating temperature range
Cooling
Upper limit
Lower limit
Heating
Upper limit
Lower limit
Table 8
The built-in protection device may prevent the appliance from operating
at temperatures outside the above range.
Condensation may form at the air outlet if the humidity is higher than
80 % and the appliance operates continuously in Cooling mode. To
prevent this, open the vertical ventilation flaps as wide as possible
(vertical relative to the ground) and set a high fan output.
When power failure occurs
This air conditioner has a memory function to store settings when a
power failure occurs.
After power recovery, the unit will automatically restart in the same
settings, which were active before the power failure, except for timer
settings.
If the timers were set before a power failure, they will need to be set
again.
Preheating function
In heating mode the indoor fan may not start for 2 to 5 minutes after the
unit is turned on, to prevent cold air from blowing out of the unit.
De-icing function
When ice forms on the heat exchanger of the outdoor unit during heating
mode, an automatic de-icer provides heat for about 5 to 10 minutes to
remove the ice. During de-icing, the inside and outside fans stop
operating and the green operation lamp K flashes slowly.
After de-icing is completed, the unit automatically resumes operation in
heating mode.
Heating efficiency
The outside air temperature greatly affects the heating efficiency. If the
heating efficiency is reduced due to low outside temperatures, use an
additional heater.
It takes time to warm up and heat the entire room because of the forced
air circulation system.
Operation
Indoor
Weather
temperature
temperature
+32 °C
+48 °C
+21 °C
–10 °C
+27 °C
+24 °C
–15 °C
51