Element Specifications; Temperature Sensor - Wolf CT15I Technical & Service Manual

Table of Contents

Advertisement

Technical Data
THIS APPLIANCE MUST BE PROPERLY GROUNDED AT ALL TIMES WHEN ELECTRICAL POWER IS APPLIED.
DO NOT GROUND THE APPLIANCE WITH THE NEUTRAL (WHITE) HOUSE SUPPLY WIRE. A SEPARATE
GROUND WIRE MUST BE UTILIZED.
IF ALUMINUM HOUSE SUPPLY WIRING IS UTILIZED, SPLICE THE APPLIANCE COPPER WIRE TO THE ALU-
MINUM HOUSE WIRING USING SPECIAL CONNECTORS DESIGNED AND CERTIFIED FOR JOINING COPPER
AND ALUMINUM. FOLLOW THE CONNECTOR MANUFACTURES RECOMMENDED PROCEDURE CAREFUL-
LY. IMPROPER CONNECTION CAN RESULT IN A FIRE HAZARD.
TO ELIMINATE THE RISK OF BURNS OR FIRE BY REACHING OVER HEATED SURFACE UNITS, CABINET
STORAGE SPACE LOCATED ABOVE THE SURFACE UNITS SHOULD BE AVOIDED. IF CABINET STORAGE IS
TO BE PROVIDED, THE RISK CAN BE REDUCED BY INSTALLING A RANGE HOOD THAT PROTECTS HORI-
ZONTALLY A MINIMUM OF 5" (127 MM) BEYOND THE BOTTOM OF THE CABINETS.

Element Specifications:

Element
Power Output
Front
1800
Rear
2200
Figure 6.1. Element Specifications.
Amperage Test:
Mode
Led's On
HI
16
HI-POWER
16
Figure 6.2. Amp draw take at L1.
Temperature Sensor: (Part of Element)
Minimum
Temperature
(K ohm)
97.21
77°F (25°C)
86°F (30°C)
79.5
122°F (50°C)
37.54
158°F (70°C)
19.15
212°F (100°C)
7.87
Figure 6.3. K Ohm Reading.
I I n n d d u u c c t t i i o o n n C C o o o o k k t t o o p p
Ohm
2 ± 10%
2 ± 10%
Zone On
Watts
Both
3600
Both
2800
Normal
(K ohm)
117.8
95.72
44.11
22.02
8.8
6-2
Diameter
6"
8 1/2"
Amp Draw
15 ± 10%
11.7 ± 10%
Maximum
(K ohm)
142.5
115
51.69
25.25
9.81