3
|
Components
To remove the expansion valve body
Service manual
68
b Expansion valve coil harness
INFORMATION
The expansion valve and coil can have a different configuration / layout.
4 Cut all tie straps that fix the expansion valve coil harness.
5 Disconnect the expansion valve coil connector from the main PCB.
6 To install the expansion valve coil, see
Prerequisite: Recuperate the refrigerant from the refrigerant circuit, see
"4.2.2 Repair
procedures" [
Prerequisite: If needed, remove any parts or insulation to create more space for
the removal.
1 Remove the expansion valve coil, see
2 Remove the putty. Keep for re-use.
a
a Putty
b Expansion valve pipe
c Expansion valve body
a Expansion valve pipe
b Expansion valve body
INFORMATION
The expansion valve and coil can have a different configuration / layout.
3 Using a valve magnet, open the expansion valve.
"3.3.2 Repair
4
 148].
"3.3.2 Repair
b
c
a
b
4
procedures" [
 67].
4
procedures" [
 67].
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
Split Comfora R32
ESIE18-01E – 2023.01